Rack Mounted Load Banks
In order to meet the requirements of the next generation of high-density, intelligent and low pue in the data center, the corresponding load of the micro module is also evolving iteratively.
PRODUCT OVERVIEW
In order to meet the requirements of the next generation of high-density, intelligent and low pue in the data center, the corresponding load of the micro module is also evolving iteratively. The rack mounted resistive load bank is an important test tool, which realizes the simulation and replacement of L2 layer equipment (conventional server, high-density server and high-density router) in the computer room through the adjustment of heat source and air volume.
PRODUCT PICTURE AND APPLICATION
PARTIAL PARAMETERS
Note: all parameters are for reference only and can be customized | |
Product name | rack load bank |
Rated voltage | AC250V |
Maximum load power | According to customer needs |
Load grading | According to customer needs |
Load accuracy (per gear) | ±2 percent |
Connection mode | Three input,independent control power input |
Control power | AC220V/50Hz |
Insulation class | F |
Air volume | The maximum air volume is 1200 ㎡/h, which supports manual mode / automatic mode and can be adjusted |
Cooling mode | Forced air cooling,forward air,rear air |
Control mode | Load switching of manual miniature circuit breaker |
Protection function | High temperature alarm(70 degree ) high temperature automatic unloading(85 degree ) |
Color | Customized |
Ambient temperature | -20 degree to 50 degree |
Humidity | Up to 100 percent |
Altitude | Up to 2500m |
Atmospheric pressure | 86 to 106kPa |
MORE SPECIFICATIONS
Power(kW) | Voltage(V) | Frequency(Hz) | Height | Loading step |
3 | 220/240 | 50/60 | 3U | 0.5kW |
3.5 | 220/240 | 50/60 | 3U | |
4 | 220/240 | 50/60 | 4U | |
4.5 | 220/240 | 50/60 | 4U | |
5 | 220/240 | 50/60 | 4U | |
6 | 220/240 | 50/60 | 6U | |
7 | 220/240 | 50/60 | 6U | |
8 | 220/240 | 50/60 | 8U | |
9 | 220/240 | 50/60 | 8U | |
10 | 220/240 | 50/60 | 8U | |
12 | 220/240 | 50/60 | 12U |
PROTECTION FUNCTION
1. Fire protection: the resistance module is separated by copper studs, and the mica plate is separated from the bottom plate to achieve the effect of fire prevention.
2. Temperature protection: alarm when the temperature reaches 55 degree and disconnect the load. After disconnecting the load, the alarm needs to be removed before restarting the equipment.
3. Overload protection: alarm when the load exceeds 3500W and disconnect the load. After disconnecting the load, it is necessary to clear the alarm before restarting the equipment.
4. Fan: the fan can realize the air volume of 0-1200, and there is a 3-minute fan to delay the heat dissipation after the operation.
Populaire tags: rack mounted load banks, China, suppliers, manufacturers, factory, customized, price, quotation